TORSION CABLE

KIFLEX MFHV

Super Fine Conductor / Fluorine Insulation / Colour coded

INTRODUCE

KIFLEX MFHV is signal interconnecting or control cable used for the high speed cable chains of manufacturing automatic machine or internal or external wiring of the industrial robots system.

CONSTRUCTION
ConductorTinned annealed copper standard acc. to IEC 60228 EN 60228, VDE 0295 Class 6
InsulationIFluorine compound
FillerFabric
Strandingin layers
WrappingSpecial non-woven Tape
SheathSpecial Poly Vinyl Chloride
Sheath ColorBlack(Color can be changed after consulation)
OUTSTANDING FEATURES
  • Small outer diameter and small bending radius

  • Continuously super flexible

  • Low friction of fluorine insulation

  • No toxicity

  • No flame propagation

  • Flame retardant and self-extinguishing

TECHNICAL DATA
Nominal Rating105oC, 300V
Insulation ResistanceIMin. 1000MΩ/km
Spark Test VoltageAC 2500V
Dielectric Test Voltage
Core/Core
AC 200V / 1 min
Core/ScreenAC 1200V / 1 min
Min. bending radius
Fixed laying
Overall diameter x 6
Flexible applicationOverall diameter x 7.5
Temperature range
fixed laying
-20oC ~ +105oC
flexble application-10oC ~ +105oC
Toxicityacc. to RoHS
Fire performanceFlame retardant and self-extinguishing
acc. to IEC 60332-1, EN 60332-1
VW-1 acc. to UL 1581 section 1080
FT1 acc. to UL 1581 section 1060
0.2 CROSS SECTION DATA SHEET
No. of Cores
x cross section
(No. / ㎟)
Conductor
strands
(EA / ㎜)
Conductor
diameter
(㎜)
Insulation
diameter
(㎜)
Overall
diameter
(㎜)
Max.
current
(A)
2 x 0.240/0.080.580.953.56.4
3 x 0.240/0.080.580.953.75.6
4 x 0.240/0.080.580.954.04.5
6 x 0.240/0.080.580.954.73.9
8 x 0.240/0.080.580.955.33.6
10 x 0.240/0.080.580.956.03.4
12 x 0.240/0.080.580.955.93.4
15 x 0.240/0.080.580.956.33.3
20 x 0.240/0.080.580.957.13.0
0.3 CROSS SECTION DATA SHEET
No. of Cores
x cross section
(No. / ㎟)
Conductor
strands
(EA / ㎜)
Conductor
diameter
(㎜)
Insulation
diameter
(㎜)
Overall
diameter
(㎜)
Max.
current
(A)
2 x 0.360/0.080.721.154.28.0
3 x 0.360/0.080.721.154.47.0
4 x 0.360/0.080.721.154.95.6
6 x 0.360/0.080.721.155.64.9
8 x 0.360/0.080.721.156.54.5
10 x 0.360/0.080.721.157.34.3
12 x 0.360/0.080.721.157.24.2
15 x 0.360/0.080.721.157.74.1
20 x 0.360/0.080.721.158.83.8
0.5 CROSS SECTION DATA SHEET
No. of Cores
x cross section
(No. / ㎟)
Conductor
strands
(EA / ㎜)
Conductor
diameter
(㎜)
Insulation
diameter
(㎜)
Overall
diameter
(㎜)
Max.
current
(A)
2 x 0.57/14/0.081.041.404.811.2
3 x 0.57/14/0.081.041.405.19.8
4 x 0.57/14/0.081.041.405.47.8
6 x 0.57/14/0.081.041.406.46.9
8 x 0.57/14/0.081.041.407.46.3
10 x 0.57/14/0.081.041.408.46.0
12 x 0.57/14/0.081.041.408.35.9
15 x 0.57/14/0.081.041.408.855.7
20 x 0.57/14/0.081.041.4010.15.3
0.75 CROSS SECTION DATA SHEET
No. of Cores
x cross section
(No. / ㎟)
Conductor
strands
(EA / ㎜)
Conductor
diameter
(㎜)
Insulation
diameter
(㎜)
Overall
diametear
(㎜)
Max.
current
(A)
2 x 0.757/20/0.081.241.705.416.0
3 x 0.757/20/0.081.241.705.714.0
4 x 0.757/20/0.081.241.706.211.2
6 x 0.757/20/0.081.241.707.39.8
8 x 0.757/20/0.081.241.708.59.0
10 x 0.757/20/0.081.241.709.68.6
1.25 CROSS SECTION DATA SHEET
No. of Cores
x cross section
(No. / ㎟)
Conductor
strands
(EA / ㎜)
Conductor
diameter
(㎜)
Insulation
diameter
(㎜)
Overall
diametear
(㎜)
Max.
current
(A)
2 x 1.257/36/0.081.662.106.321.6
3 x 1.257/36/0.081.662.106.718.9
4 x 1.257/36/0.081.662.107.315.1
6 x 1.257/36/0.081.662.108.613.2