SILICON CABLE

UL STYLE NO.3122 SILICON CABLE

SILICON INSULATED CABLE

CONSTRUCTION
UL Style No.3122
UL File No.E477181
StandardUL Subject 758
UseInternal wiring of appliances
Max. Voltage300V
temperatures exceeding200℃
TECHNICAL DATA
ConductorInsulationCompletion Diameter
(mm)
Spark Test Voltage
(AC V)
Res. Insulation
(MΩ/km,at20℃)
AWGComposition
(EA / mm)
Diameter
(mm)
Silicon Thickness
(mm)
Glass fiber
(mm)
261/0.400.400.400.201.602000100
7/0.160.490.400.201.692000100
241/0.500.500.400.201.702000100
7/0.2030.610.400.201.812000100
221/0.600.600.400.201.802000100
66/0.080.750.400.201.952000100
201/0.820.820.400.202.022000100
21/0.180.950.400.202.152000100
1835/0.181.230.400.202.432000100
1655/0.181.540.400.202.742000100