BUS CABLE

KICC 110SB-F

Foamed polyethylene Insulation / Colour coded / Braid Shield

CONSTRUCTION
ConductorAnnealed bare copper standard acc. to IEC 60228 EN 60228, VDE 0295 Class 2
InsulationISpecial foamed polyethylene
FillerIf necessary
Strandingin layers
WrappingAluminiwm Mylar Foil Shield Tape
Drain WireTinned annealed copper standard acc. to IEC 60228 EN 60228, VDE 0295 Class 5
ShieldTinned copper braid shield
SheathSpecial Poly Vinyl Chloride
Sheath ColorDark Brown
OUTSTANDING FEATURES
  • CLPA Certified CC-LINK Ver. 1. 10

  • Standard CC-LINK Cable for high speed data transmission

  • Corresponds to 10 Mbps transmission

  • Variations prepared to match various use enviroment.

  • Good EMC characteristic

  • No toxicity

  • No flame propagation

  • Flame retardant and self-extinguishing

TECHNICAL DATA
Nominal Rating80oC, 300V
Insulation ResistanceIMin. 10000MΩ/km
Spark Test VoltageAC 500V
Dielectric Test Voltage
Core/Core
AC 500V / 1 min
Core/ScreenAC 300V / 1 min
Conductor ResistanceMax. 37.80Ω/km
CapacitanceMax. 60pF/m
Characteristics
impedance
1 MHz110 ± 15Ω
5 MHz110 ± 6Ω
Attenuation1 MHzMax. 1.6 dB/100m
5 MHzMax. 3.5 dB/100m
Each Equipment
Connection
BlueDA
WhiteDB
YellowDG
Drain WireSLD
Toxicityacc. to RoHS
Fire performanceFlame retardant and self-extinguishing
acc. to IEC 60332-1, EN 60332-1
VW-1 acc. to UL 1581 section 1080
FT1 acc. to UL 1581 section 1060
DATA SHEET
No. of Cores
x cross section
(No. / ㎟)
Conductor
strands
(EA / ㎜)
Conductor
diameter
(㎜)
Insulation
diameter
(㎜)
Overall
diameter
(㎜)
3 x 0.57/0.320.642.508.0