UL STYLE NO. 2969 ELECTRONIC CABLE
– 다심 컴퓨터 케이블
- 전기, 전자기기의 신호전송 및 전자적 컴퓨터와 전기장치 Class 2 회로 안의 외부 연결용
- VTR, TV, 스테레오 수신기 등의 리모콘 제어용
- VTR카메라와 뷰파인더, 오디오, 비디오 장비의 연결용
- 도체(Conductor) :
- TInned Copper Strands acc. to ASTM B33
- Base : IEC 60228 Class 5
- OEM : IEC 60228 Application
- 절연체(Insulation) :
- UL Style No. 1571 Specification Application
- 테핑(Wrapping) :
- Aluminium Mylar Tape
- 차폐층 (Screen)
- Tinned Copper braid Shield
- 시스체 (Sheath)
- UL Style no. 2969 Specification Application
- 적용규격(Standard) :
- UL 758, UL 1581
- 제품 정격(Style Rating) :
- 30V, 80°C
- 스파크 절연 테스트(Spark Test Voltage)
- AC 500V
- 내전압 테스트(Dielectri Test Voltage)
- AC 500V
- 난연성 테스트 (Fire Performance)
- Flame retardant and self-extinguishing
- VW-1 acc. to UL 1581 section 1080
- FT1 acc. to UL 1581 section 1060
- Temp. Range
- Fixed Application : - 15°C ~ 70°C
- Flexible Application : No Specified
- 특징 (Features) :
- Flexible and electrical character is excellent.
- Flammability excellent.
- 제품허용공차 : ±5% 내외 (Tolerance : ±5%)
- 일반화된 특정 제품의 구조가 없이 ODM방식의 제작이 이루어지고 있는 제품군으로서 협의에 의하여 UL 758 및 UL 1581에 적합하게 제작 가능.
- CE Marking 가능. (단, 본사와 협의 후 ODM 조건)
Cable Detail Planning Data (케이블 설계 자료)
Item | Detail Contents | ||
Conductor | Certification AWG Range : 40AWG minimum Workable AWG Range : 28AWG ~ 4AWG |
||
Insulation | Insulation Thickness : 2mils min. at any point / 100mils max. | ||
Wrapping | (Optional) Minimum at any point : 5mils | ||
Covering | (Optional) Tinned Copper screw shield or Braid Shield | ||
Screen | (Optional) Tinned Copper screw shield or Braid Shield | ||
Sheath | #Dia. of cable under Jacket in Inches | Minimum Average | Minimum At any point |
0.425 or less 0.426 ~ 0.700 0.701 ~ 1.000 1.001 ~ 1.500 1.501 ~ 2.500 2.501 and Larger | 30 45 60 80 110 140 | 24 36 48 64 88 112 |
|
# -Major dia if cable is flat or oval. (Unit : MILS) |
Cable Detail Data (케이블 세부 자료)
Conductor | Insulation | Tape Material | Braid Shield | Sheath | Max. Conductor Resistance at 20°C(Ω/km) | Min. Insulation Resistance at 15.6°C(MΩ · km) |
||||
AWG Size | No. of Pair | Material | Thickness | Material | Coverage (%) | Material | Thickness (mm) |
|||
24 ~ 30 | 5 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |
24 ~ 30 | 6 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |
24 ~ 30 | 7 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |
24 ~ 30 | 10 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |
24 ~ 30 | 15 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |
24 ~ 30 | 20 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |
24 ~ 30 | 25 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |
24 ~ 30 | 30 | PVC | 0.18 or 0.40 | AL Mylar | Tinned Annealed Copper | Min. 70 | PVC | 1.00 | 5 | 500 |