CONTINUOUS FLEX CABLE
KITRONIC DEVICENET
Fine Conductor / Foamed PE & PVC Insulation / Braid Shielded
INTRODUCE
DeviceNet is a bus system developed by Allen Bradley (Rockwell Automation). These cables are used to interconnect various industrial devices, such as SPS controls or limit switches. The special characteristic of this bus system is that a data pair and a power supply pair are integrated in one cable. These cables with PVC sheath are designed for fixed installation.
CONSTRUCTION
Conductor | Tinned annealed copper standard acc. to IEC 60228 EN 60228, VDE 0295 Class 6 |
Insulation | 18, 24AWG : Foamed Polyethylene compound 15, 22AWG : Special Poly Vinyl Chloride |
Insulation Color | 18, 24AWG : White, Blue 15, 22AWG : Black, Red |
Filler | If necessary |
Wrapping | Aluminium Mylar Foil Shield Tape |
Drain Wire | Tinned annealed copper standard acc. to IEC 60228 EN 60228, VDE 0295 Class 5 |
Shield | Tinned copper wire Braid Shielded |
Sheath | Special Poly Vinyl Chloride |
Sheath Color | Gray |
OUTSTANDING FEATURES
Certified ODVA DeviceNet
Standard DeviceNet Cavle for data transmission
Variations prepared to match various use environment
Good EMC characteristics
No toxicity
No flame propagation
Flame retardant and self-extinguishing
TECHNICAL DATA
Certification | DeviceNet, UL | ||
Nominal Rating | 80oC, 300V | ||
Spark Test VoltageI | AC 500V | ||
Dielectric Test Voltage | Core/Core | AC 500V / 1 min |
|
Core/Screen | AC 300V / 1 min | ||
Conductor Resistance | Thick | 18AWG | Max. 22.60 Ω/km |
15AWG | Max. 11.80 Ω/km | ||
Thin | 24AWG | Max. 91.80 Ω/km | |
22AWG | Max. 57.40 Ω/km | ||
Insulation Resistance | Thick | 18AWG | Min. 10,000 MΩ/km |
15AWG | Min. 100 MΩ/km | ||
Thin | 24AWG | Min. 10,000 MΩ/km | |
22AWG | Min. 100 MΩ/km | ||
Mutual Capacitance | Max. 39.8 nF/m | ||
Characteristics impedance | 120 ± 12 Ω | ||
Attenuation | Thick | 125kHz | Max. 0.42 dB/100m |
500kHz | Max. 0.81 dB/100m | ||
Thin | 125kHz | Max. 0.95 dB/100m | |
500kHz | Max. 1.64 dB/100m | ||
Toxicity | acc. to RoHS | ||
Fire performance | Flame retardant and self-extinguishing acc. to IEC 60332-1, EN 60332-1 VW-1 acc. to UL 1581 section 1080 FT1 acc. to UL 1581 section 1060 |
0.2 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Conductor strands (EA / ㎜) | Conductor diameter (㎜) | Insulation diameter (㎜) | Overall diameter (㎜) | Max. current (A) |
2 x 0.2 | 40/0.08 | 0.58 | 1.05 | 3.9 | 4.0 |
3 x 0.2 | 40/0.08 | 0.58 | 1.05 | 4.2 | 3.5 |
4 x 0.2 | 40/0.08 | 0.58 | 1.05 | 4.5 | 2.8 |
6 x 0.2 | 40/0.08 | 0.58 | 1.05 | 5.2 | 2.5 |
8 x 0.2 | 40/0.08 | 0.58 | 1.05 | 5.9 | 2.3 |
10 x 0.2 | 40/0.08 | 0.58 | 1.05 | 6.6 | 2.2 |
12 x 0.2 | 40/0.08 | 0.58 | 1.05 | 6.5 | 2.1 |
15 x 0.2 | 40/0.08 | 0.58 | 1.05 | 7.0 | 2.1 |
20 x 0.2 | 40/0.08 | 0.58 | 1.05 | 7.8 | 1.9 |
0.3 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Conductor strands (EA / ㎜) | Conductor diameter (㎜) | Insulation diameter (㎜) | Overall diameter (㎜) | Max. current (A) |
2 x 0.3 | 60/0.08 | 0.72 | 1.25 | 4.4 | 4.8 |
3 x 0.3 | 60/0.08 | 0.72 | 1.25 | 4.6 | 4.2 |
4 x 0.3 | 60/0.08 | 0.72 | 1.25 | 5.1 | 3.4 |
6 x 0.3 | 60/0.08 | 0.72 | 1.25 | 5.8 | 2.9 |
8 x 0.3 | 60/0.08 | 0.72 | 1.25 | 6.7 | 2.7 |
10 x 0.3 | 60/0.08 | 0.72 | 1.25 | 7.5 | 2.6 |
12 x 0.3 | 60/0.08 | 0.72 | 1.25 | 7.4 | 2.5 |
15 x 0.3 | 60/0.08 | 0.72 | 1.25 | 7.9 | 2.5 |
20 x 0.3 | 60/0.08 | 0.72 | 1.25 | 9.0 | 2.3 |
0.5 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Conductor strands (EA / ㎜) | Conductor diameter (㎜) | Insulation diameter (㎜) | Overall diameter (㎜) | Max. current (A) |
2 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 5.3 | 6.4 |
3 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 5.6 | 5.6 |
4 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 6.1 | 4.5 |
6 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 7.2 | 3.9 |
8 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 8.3 | 3.6 |
10 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 9.4 | 3.4 |
12 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 9.3 | 3.4 |
15 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 10.0 | 3.3 |
20 x 0.5 | 7/14/0.08 | 1.04 | 1.65 | 11.5 | 3.0 |
0.75 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Conductor strands (EA / ㎜) | Conductor diameter (㎜) | Insulation diameter (㎜) | Overall diameter (㎜) | Max. current (A) |
2 x 0.75 | 7/20/0.08 | 1.24 | 2.00 | 6.1 | 8.8 |
3 x 0.75 | 7/20/0.08 | 1.24 | 2.00 | 6.5 | 7.7 |
4 x 0.75 | 7/20/0.08 | 1.24 | 2.00 | 7.1 | 6.2 |
6 x 0.75 | 7/20/0.08 | 1.24 | 2.00 | 8.3 | 5.4 |
8 x 0.75 | 7/20/0.08 | 1.24 | 2.00 | 9.7 | 5.0 |
10 x 0.75 | 7/20/0.08 | 1.24 | 2.00 | 11.2 | 4.7 |
1.25 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Conductor strands (EA / ㎜) | Conductor diameter (㎜) | Insulation diameter (㎜) | Overall diameter (㎜) | Max. current (A) |
2 x 1.25 | 7/36/0.08 | 1.66 | 2.55 | 7.3 | 12.8 |
3 x 1.25 | 7/36/0.08 | 1.66 | 2.55 | 7.7 | 11.2 |
4 x 1.25 | 7/36/0.08 | 1.66 | 2.55 | 8.5 | 9.0 |
6 x 1.25 | 7/36/0.08 | 1.66 | 2.55 | 10.2 | 7.8 |