FLEXIBLE CONTROL CABLE
KIFLEX SVV
Bare Anneal Copper / Color Core PVC Insulation / PVC Control Cable
INTRODUCE
KIFLEX SVV is signal interconnecting or power supply cable used for the high speed cable chanins of manufacturing automatic machine or arm of the industrial robots.
CONSTRUCTION
Conductor | Tinned annealed copper standard acc. to IEC 60228 EN 60228, VDE 0295 Class 6 |
InsulationI | Special Polyethylene |
Filler | Fabric |
Stranding | in layers |
Wrapping | Special non-woven Tape |
Sheath | Special Polyurethane |
Sheath Color | Black(Color can be changed after consulation) |
TECHNICAL DATA
Nominal Rating | 0.5㎟ ~ 1.5㎟ : Uo/U 300/500V 2.5㎟ ~ 50㎟ : Uo/U 450/750V |
|
Testing Voltage | C / C 400V | |
Min. Bending radius | Fixed laying | 4 x d |
Flexible application | 15 x d | |
Temperature Range | Fixed laying | -30oC ~ +70oC |
Flexible application | -5oC ~ +70oC | |
File performance | Flame relardanl and self - exlinguishing Acc. 10 IEC |
|
Oil Resistance | Acc. to internal standard |
0.5 CROSS SECTION DATA SHEET
No. of Cores x Cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
2 x 0.50 | 0.21 | 4.8 | 9.6 | 33 |
3 x 0.50 | 0.21 | 5.1 | 14.4 | 40 |
4 x 0.50 | 0.21 | 5.5 | 19.2 | 47 |
5 x 0.50 | 0.21 | 6.2 | 24.0 | 61 |
7 x 0.50 | 0.21 | 6.7 | 33.6 | 74 |
0.75 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
2 x 0.75 | 0.21 | 5.6 | 14.4 | 46 |
3 x 0.75 | 0.21 | 5.7 | 21.6 | 52 |
4 x 0.75 | 0.21 | 6.2 | 28.8 | 64 |
5 x 0.75 | 0.21 | 6.7 | 36.0 | 78 |
7 x 0.75 | 0.21 | 7.5 | 50.4 | 100 |
1.0 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
2 x 1.00 | 0.21 | 5.5 | 19.2 | 48 |
3 x 1.00 | 0.21 | 6.1 | 28.8 | 63 |
4 x 1.00 | 0.21 | 6.5 | 38.4 | 75 |
5 x 1.00 | 0.21 | 7.1 | 48.0 | 92 |
7 x 1.00 | 0.21 | 8.0 | 67.2 | 120 |
1.5 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
2 x 1.50 | 0.26 | 6.2 | 28.8 | 64 |
3 x 1.50 | 0.26 | 6.5 | 43.2 | 79 |
4 x 1.50 | 0.26 | 7.6 | 57.6 | 103 |
5 x 1.50 | 0.26 | 8.0 | 72.0 | 121 |
7 x 1.50 | 0.26 | 8.4 | 100.8 | 160 |
2.5 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
2 x 2.50 | 0.26 | 8.8 | 48.0 | 121 |
3 x 2.50 | 0.26 | 9.5 | 72.0 | 151 |
4 x 2.50 | 0.26 | 10.6 | 96.0 | 190 |
5 x 2.50 | 0.26 | 11.6 | 120.0 | 232 |
7 x 2.50 | 0.26 | 12.8 | 168.0 | 297 |
4.0 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
3 x 4.00 | 0.31 | 10.8 | 115.2 | 213 |
4 x 4.00 | 0.31 | 12.0 | 153.6 | 267 |
5 x 4.00 | 0.31 | 13.1 | 192.0 | 327 |
6.0 CRESS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
2 x 6.00 | 0.31 | 11.2 | 115.2 | 239 |
3 x 6.00 | 0.31 | 12.7 | 172.8 | 303 |
4 x 6.00 | 0.31 | 14.1 | 230.4 | 381 |
5 x 6.00 | 0.31 | 15.7 | 288.0 | 466 |
7 x 6.00 | 0.31 | 17.3 | 403.2 | 613 |
10.0 CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
3 x 10.0 | 0.41 | 15.8 | 288.0 | 492 |
4 x 10.0 | 0.41 | 17.8 | 384.0 | 627 |
5 x 10.0 | 0.41 | 19.7 | 480.0 | 783 |
Etc. CROSS SECTION DATA SHEET
No. of Cores x cross section (No. / ㎟) | Largest Single Wire (㎜) | Outer - Ø ± 5% (㎜) | Copper Figure (kg/km) | Cable Weight (kg/km) |
4 x 16.0 | 0.41 | 21.1 | 614.4 | 935 |
4 x 25.0 | 0.41 | 25.5 | 960.0 | 1456 |
4 x 35.0 | 0.41 | 28.8 | 1344.0 | 1978 |